HC-10手册_page-0001.jpg

1.Testing burning and pinpointing, direct resistance measurement, voltage and current limiter

2.Multiple signal reception methods used for different cable laying scenes(not just direct burial)

3.Mains and battery operated

4.Only one HV connection cable

5.Automatic evaluation and recommend test methods Step voltage method for cable sheath fault pin-pointing

6.Easy and comfortable operation via touch screen and rotary encoder

微信截图_20240808172051.jpg

The HC-10 is used for cable and cable sheath testing, and for the pin-pointing of cable sheath faults and cable faults due to earth contact. The operation of the system is achieved via touch screen and rotary encod- er.Multiple signal reception methods used for different cable laying scenes:

·Cable trench or tunnel

·Cable pipe

·Direct burial

The very powerful 10 kV DC source allows HV cables to be tested..A multi-section facility permits the entry of cable segments with different parameters. Difficult cable faults can be “burned” thanks to the available high current.

HC-10 Sheath fault location system manufacture

微信截图_20240808141005.jpg

Only one HV connection cable and through the touch screen or rotary encoder, you can follow the system instructions to complete the test.The system will automatically evaluate the insulation resistance of the sheath and recommend test methods.

HC-10 Sheath fault location system details

图片3.jpg

微信截图_20240809113607.jpg

1.Built in lithium battery, with a battery life greater than 6 hours

2.Portable suitcase design for easy outdoor movement

微信截图_20240809113657.jpg

微信截图_20240808140730.jpg

As far as we know, there are many ways to lay cables: in suburbs, they are mainly laid directly buried; in cities, there are also pipelines, cable trench or tunnel.Sheath failures in different laying scenarios require different positioning methods.

图片4(0f39488b10).jpg

Stethoscope mode

Suitable for cable trench or tunnel.Signals exist before fault point and disap- pears behind fault point.

图片5(477b650093).jpg

Probe mode

Suitable for cable pipe.Near the fault point, the received signal value is maximum.

图片6(6467aa469e).jpg

Step voltage mode

suitable for direct burial.Judge according to the color of the arrow whether it is closer to the red earth spike or the black earth spike.

微信截图_20240808140712.jpg

TECHNICAL DATA
Output voltage 0 … 10kV
Output current 150mA
Test voltage 0 … −10kV
Insulation resistance test 0…650MΩ
Maximum permitted capacity 10 uF
of the test object
Pinpointing 0 -10 kV DC, pulsed selectable ; 0.5:1 / 1:2 / 1.5:3.5
Power supply (rated voltage) AC 90V…240V,50/60Hz
Battery Built-in battery (615Wh)
Endurance (battery powered) 6h
Power consumption max. 800 VA
Display 8000 x 480 LCD, 1000cd/m²
Operating temperature -20℃...+55℃
Storage temperature -40℃...+65℃
Dimensions (W x H x D) 500*457*305mm
Weight 18.5KG
Protection rating IP54